Method and references
Glass Wind Load follows ASTM E1300. This page summarises each step of the calculation and lists every published source the calculator relies on.
How a result is calculated
- Non-factored load (NFL). Read from the E1300 charts for the glass thickness and support. A laminate uses its E1300 thickness designation (the ply minimums plus the interlayer, rounded down to a standard thickness) where that is thinner than the sum of its plies. Four-sided charts are interpolated between digitised contours with a smooth cubic surface in logarithmic coordinates. Panels outside the charted range are refused, never extrapolated. One- and two-sided charts are straight lines on logarithmic axes and are interpolated the same way.
- Glass type factor (GTF). From E1300 Tables 1 to 3 for annealed, heat-strengthened or tempered glass, and for short (3 s) or long (30 day) loads.
- Load-share factor (LSF). Applies to double glazing. Each lite takes a share of the pressure in proportion to its stiffness, t³, using E1300 minimum thicknesses (Appendix X3).
- Load resistance. LR = NFL × GTF × LSF. A lite passes when the applied pressure does not exceed LR.
- Deflection, four sides supported. The E1300 centre-deflection formula w = t·exp(r₀ + r₁x + r₂x²), with Young's modulus 71.7 GPa. At low pressure, where that formula is not valid, small-deflection plate theory is used, joined smoothly to the formula. Laminates use the layered (no shear transfer) thickness, which gives an upper bound. Above 20 times the glass thickness the formula is not used: the deflection is shown as more than that bound and the deflection check fails.
- Deflection, one or two sides supported. Taken from the E1300 beam charts. They follow simple beam theory.
- Weight. Glass at 2,500 kg/m³ plus the interlayer.
The method was checked against the worked examples published in E1300. An independent calculation from first principles reproduced the four-sided charts to within about 3% on 16 panels: a large-deflection plate analysis combined with the glass failure prediction model. That agreement depends on how biaxial stress is treated in the failure model; the simplest treatment differs by 7–26%. Results are still indicative: see the terms of use.
References
Standard
- ASTM E1300-16, Standard Practice for Determining Load Resistance of Glass in Buildings. ASTM International.Used for: Load resistance LR = NFL × GTF × LSF; non-factored load charts (four-, two- and one-sided); glass type factors (Tables 1 to 3); minimum thicknesses (Table 4); load-share factors (Appendix X3, Tables 5 and 6); centre deflection formula (Appendix X1); laminated nominal thickness (3.2.4.1).
- ASTM E1300-24, the current edition of the same practice.Used for: Cross-check of the glass type factors and load-share values.
- ASTM E1300-04e1 (superseded edition), Annex A2 and appendix worked examples.Used for: Published worked examples the calculator reproduces (non-factored loads, deflection, insulating-glass load sharing).
Glass strength and plate behaviour
- Beason, W. L. and Morgan, J. R. (1984). Glass failure prediction model. Journal of Structural Engineering, 110(2), 197–212.Used for: The failure model behind the non-factored load charts (probability of breakage 8/1000, surface flaw parameters m = 7, k = 2.86 × 10⁻⁵³ N⁻⁷m¹²), used to re-derive the charts independently.
- Vallabhan, C. V. G. (1983). Iterative analysis of nonlinear glass plates. Journal of Structural Engineering, 109(2), 489–502.Used for: Large-deflection (membrane) behaviour of glass plates, the basis of the E1300 charts and deflection formula.
- Timoshenko, S. and Woinowsky-Krieger, S. (1959). Theory of Plates and Shells, 2nd ed. McGraw-Hill. §30 and Table 8.Used for: Small-deflection plate theory (Navier series) for low pressures and the bending preview; von Kármán equations for the independent check.
- Massachusetts Institute of Technology OpenCourseWare: plate bending and beam deflection notes.Used for: Uniformly loaded simply supported plate; cantilever and simply supported beam deflection (bending preview).
Laminated and insulating glass
- Galuppi, L. and Royer-Carfagni, G. (2012). The effective thickness of laminated glass plates. Journal of Mechanics of Materials and Structures, 7(4), 375–400.Used for: Effective thickness of laminates; the no-shear-transfer (layered) bound used for laminate deflection.
- Kuraray. SentryGlas ionoplast interlayer product information.Used for: Interlayer shear transfer bounds; ionoplast density 0.95 g/cm³.
- Kuraray Trosifol. PVB interlayer technical data (typical density 1.07 g/cm³).Used for: PVB density for laminate weight.
- NASA Glenn Research Center. Equation of state (ideal gas).Used for: Gas-cavity pressure–volume relation in the double-glazing bending preview.
Glass material properties
- National Glass Association. FM05-12, Physical and Mechanical Properties of Typical Soda-Lime Float Glass (2023).Used for: Young's modulus 71.7 GPa (10.4 × 10⁶ psi), Poisson's ratio 0.22 and density 2,500 kg/m³.
- Pilkington. ATS-129, Properties of Soda-Lime Silica Float Glass.Used for: Cross-check of the elastic constants and density.
Numerical methods and software
- SciPy 1.13.1, CloughTocher2DInterpolator (piecewise cubic, C1-smooth interpolation on a Delaunay triangulation).Used for: Interpolating the digitised four-sided charts, in logarithmic coordinates.
- NumPy 1.26.4.Used for: Numerical arrays.
- Django 5.2.18.Used for: Web application.
- ReportLab 4.2.5.Used for: PDF calculation reports.
- htmx 2.0.8.Used for: Updating results in the page without reloading.